Supply and Delivery of Five (5) units Electronic Tilt Systems: Data Logger/Data Taker

June 4, 2018

REQUEST FOR QUOTATION
TO ALL INTERESTED SUPPLIERS:

The Philippine Institute of Volcanology and Seismology (PHIVOLCS) hereby invites all interested suppliers to quote their lowest price on the item/s listed below, subject to the conditions stated below, stating the shortest time of delivery and submit sealed quotation to BAC Secretariat addressed to the BAC Chairman at PHIVOLCS located at C.P. Garcia Avenue, UP Campus, Diliman, Quezon City not later than 5:00 P.M. of June 8, 2018.  The ABC is Php 1,000,000.00:

  • Five (5) units Electronic Tilt System:  Data Logger/Data Taker

–       Max sampling rate (Hz): 40

–       Analog Inputs:  15 (2-wire common reference)

10 (2-wire isolated)

5 (3 and 4 wire isolated)

–       Analog Input Voltage/Current/Resistance/Frequency:

±30m, 300m, 3000m, 50000mVDC/ ±30mA/ 1MΩ/ 450kHz

–       Analog Voltage Accuracy:  ±0.15 Reading  + (Full Scale Reading * 0.01%)

–       Effective Resolution:  18 bits

–       Analog Outputs:  1

–       Analog Output Voltage/Current:  10m-10000mVDC/ 0-24mA

–       Excitation:  Analog Channel – selectable 2µA, 250µA or

2.5mA precision current source

4.5V voltage source or switched external supply

Switchable 12V/5 regulated power output (max 300mA)

–       Digital IO:  8 bi-directional channels

–       Low Speed counters (8) shared with digital inputs

–       Dedicated high speed counters (4) or 2 phase encoder

–       Communication Port:  Ethernet, RS232/RS422/RS485 serial sensor, RS232 host port, USB Port

–       Data Storage: 128MB (upgradable to 2GB)

–       Vibrating Wire Supported:  Yes

–       Protocols Supported:  Modbus, FTP, HTTP, XML, SMTP, NTP, SDI-12

–       CEM20 Expansion Module supported:  Yes

–       Power Requirements:  10-30 VDC

–       Internal Battery:  6Vdc 1.2Ah Lead Acid

–       Real Time Clock Accuracy:  ± 1 min/year (0°C to 40°C); ± 4 min/year (-40°C to 70°C)

–       Weight:  <2.0kg

–       Operating Temperature Range:  -45°C to 70°C

–       Warranty:  3 years

Conditions:

  1. All entries must be typewritten.
  2. Delivery period, ASAP.
  3. Warranty for required for equipment shall be for a minimum period of one (1) year from date of acceptance by the end-user
  4. Price validity period must be for a period of one hundred (120) calendar days
  5. G-EPS Registration Certificate shall be attached upon submission of

the requested quotation

  1. Suppliers shall submit original brochures showing certifications of the

equipment being offered.

Brand and Model  : __________________

Delivery period     : __________________

Warranty               : __________________

Price Validity        : __________________

 

BARTOLOME C. BAUTISTA

BAC Chairperson